ISO 20890-1:2020

مواصفة قياسية دولية   الإصدار الحالي · اعتمدت بتاريخ ١٢ يونيو ٢٠٢٠

Guidelines for in-service inspections for primary coolant circuit components of light water reactors — Part 1: Mechanized ultrasonic testing

ملفات الوثيقة ISO 20890-1:2020

الإنجليزية 33 صفحات
الإصدار الحالي
USD 194.69

مجال الوثيقة ISO 20890-1:2020

This document gives guidelines for pre-service-inspections (PSI) and in-service inspections (ISI) with mechanized ultrasonic test (UT) devices on components of the reactor coolant circuit of light water reactors. This document is also applicable on other components of nuclear installations.

Mechanized ultrasonic inspections are carried out in order to enable an evaluation in case of

— fault indications (e.g. on austenitic weld seams or complex geometry),

— indications due to geometry (e.g. in case of root concavity),

— complex geometries (e.g. fitting weld seams), or

— if a reduction in the radiation exposure of the test personnel can be attained in this way.

Ultrasonic test methods are defined for the validation of discontinuities (volume or surface open), requirements for the ultrasonic test equipment, for the preparation of test and device systems, for the implementation of the test and for the recording.

This document is applicable for the detection of indications by UT using normal-beam probes and angle-beam probes both in contact technique. It is to be used for UT examination on ferritic and austenitic welds and base material as search techniques and for comparison with acceptance criteria by the national referencing nuclear safety standards. Immersion technique and techniques for sizing are not in the scope of this document and are independent qualified.

NOTE Data concerning the test section, test extent, inspection period, inspection interval and evaluation of indications is defined in the applicable national nuclear safety standards.

Unless otherwise specified in national nuclear safety standards the minimum requirements of this document are applicable. This document does not define:

— extent of examination and scanning plans;

— acceptance criteria;

— UT techniques for dissimilar metal welds and for sizing (have to be qualified separately);

— immersion techniques;

— time-of-flight diffraction technique (TOFD).

It is recommended that UT examinations are nearly related to the component, the type and size of defects to be considered and are reviewed in specific national inspection qualifications.

الأكثر مبيعاً

GSO 150-2:2013
 
مواصفة قياسية خليجية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
YSMO GSO 150-2:2020
GSO 150-2:2013 
لائحة فنية يمنية
فترات صلاحية المنتجات الغذائية - الجزء الثاني : فترات الصلاحية الاختيارية
YSMO GSO 2055-1:2020
GSO 2055-1:2015 
مواصفة قياسية يمنية
الأغذية الحلال – الجزء الأول : الاشتراطات العامة للأغذية الحلال
GSO 2055-1:2015
 
لائحة فنية خليجية
الأغذية الحلال – الجزء الأول : الاشتراطات العامة للأغذية الحلال

اعتمدت مؤخراً

ISO 18990:2025
 
مواصفة قياسية دولية
Measurement of radioactivity in urine-238Pu, 239Pu and 240Pu — Test method using alpha spectrometry or ICP-MS
ISO 11929-3:2025
 
مواصفة قياسية دولية
Determination of the characteristic limits (decision threshold, detection limit and limits of the coverage interval) for measurements of ionizing radiation — Fundamentals and application — Part 3: Applications to unfolding methods
ISO 11929-2:2025
 
مواصفة قياسية دولية
Determination of the characteristic limits (decision threshold, detection limit and limits of the coverage interval) for measurements of ionizing radiation — Fundamentals and application — Part 2: Advanced applications
ISO 18243:2025
 
مواصفة قياسية دولية
Electrically propelled mopeds and motorcycles — Test specifications and safety requirements for lithium-ion battery systems